Page 1 of 1
Please enter your Name and Email to proceed further

Test Questions

Question 1

Pregunta

What amperage is the fuse that is used on the P1020-K in the battery box?

Respuesta

5 amp

2 amp

30 amp

Question 2

Pregunta

The liftgate battery light on the direct nose box is blinking green, what does the indicate?

Respuesta

Batteries are below 12.0 volts

Batteries are above 12.4 volts

Batteries are above 13.2 Volts

Question 3

Pregunta

Inside the battery box, What position should the 1-OFF-2 selector switch be in for the Purkey’s liftgate charging system?

Respuesta

1

Off

2

Question 4

Pregunta

If the Direct box has no lights on it, which of the following is not a possible reason?

Respuesta

1-2 selector switch is in the wrong position

30 amp breaker is tripped

Solar is charging the batteries

2 amp fuse on the P1020-K plate is blown

Question 5

Pregunta

What is the name of the charging system for the Pepsi’s spec?

Respuesta

Direct-01

Direct-21

1.21 Gigi watts

Question 6

Pregunta

The orange wire on the P1020-K plate routes to the Direct controller, What is the orange wires purpose?

Respuesta

Turn the converter off/on

Supply power to charge the batteries

Power the Direct box

Question 7

Pregunta

The Status is mounted where?

Respuesta

Nose of the trailer

Side of the battery box

Liftgate platform

Question 8

Pregunta

The 200 amp circuit breaker is wired between the liftgate batteries and the master disconnect switch

Respuesta

True

False

Question 9

Pregunta

It is ok to replace the 200 amp circuit breaker with a 150 amp circuit breaker

Respuesta

True

False

Question 10

Pregunta

How often do you grease the platform pivots?

Respuesta

Daily

Weekly

Quarterly

Annually

Question 11

Pregunta

When checking the oil level to ensure it is at the proper level, the platform should be in what position?

Respuesta

Open and lowered to the ground

Closed and lowered to the bottom stops

Closed and all the way up

Folded and lowered to the ground

Question 12

Pregunta

What is the BMR-55 raise speed time frame?

Respuesta

12-27 Seconds

13-26 Seconds

8-22 Seconds

9-21 Seconds

Question 13

Pregunta

The recommended clearance between the columns and the runner pad should be?

Respuesta

Zero, the pad should ride on the runner column

The thickness of two business cards

.012" to .025" using a thickness gauge

either B or C

Question 14

Pregunta

The tip of the platform does not require adjustment if it is _____ or less of the runners touching the ground.

Respuesta

1"

2.5"

2.0"

3.0"

Question 15

Pregunta

How much grease should be in the columns of a BMR gate when performing maintenance?

Respuesta

A light film

A ¼ inch layer

None at all

Should be lubed with spray lithium Grease

Question 16

Pregunta

Maxon uses positive lock connectors on all spade terminals that have a mechanical detent that needs to be pressed to remove the wire?

Respuesta

True

False

Question 17

Pregunta

It is only required to verify the operation of the liftgate with the Master switch on position 1

Respuesta

True

False

Question 18

Pregunta

When order new Maxon liftgate decals you will need to provide the ____________

Respuesta

Year make and model of the truck or trailer

Serial number of truck or trailer

Model of liftgate and year

Serial number of the liftgate

Question 19

Pregunta

Maxon uses open harnesses to allow for quick and easy repairs

Respuesta

True

False